Industrial RCD Services

Industrial RCD Services

Compare electricians for industrial RCD protection: three-phase RCDs, discrimination, RCD types for drives and periodic testing under EAWR.

Service overview

Industrial RCD Services: what to know

Why RCD protection matters in industry


Industrial sites bring together heavy equipment, damp or dusty conditions, portable tools and long cable runs, so the risk of electric shock is higher than in most buildings. A residual current device (RCD) monitors the balance of current in a circuit and switches off the supply within a fraction of a second if current is leaking to earth, for example through damaged insulation, a faulty tool or a person. That fast disconnection reduces the risk of a fatal shock and of fires caused by earth leakage.


RCDs are particularly important in wash-down areas, outdoor yards, workshops and anywhere portable equipment is plugged in and moved around. The qualified industrial electricians you compare through Kilowatts UK can assess where protection is needed across your site.


What the rules require


The Electricity at Work Regulations 1989 require employers to make sure electrical systems are constructed and maintained to prevent danger, so far as is reasonably practicable. New work is designed to BS 7671:2018+A4:2026, the current IET Wiring Regulations, which requires 30 mA RCD protection for mobile equipment rated up to 32 A used outdoors and, in general, for socket-outlets rated up to 32 A. In non-domestic premises a documented risk assessment can justify omitting it from specific sockets. On construction sites, reduced low voltage (110 V) supplies are commonly used for portable tools.


Designing RCD protection for industrial loads


Industrial installations need more thought than a home consumer unit:



  • Three-phase RCDs and RCBOs protect three-phase final circuits and equipment.

  • Discrimination. Time-delayed (Type S) RCDs upstream, with 30 mA devices on final circuits, mean a fault trips only the nearest device rather than a whole distribution board.

  • The right RCD type. Variable speed drives, inverters and some electronic equipment can produce fault currents that ordinary devices may not detect, so Type F or Type B RCDs may be needed. Type AC devices are restricted.

  • Nuisance tripping. Leakage from many items of equipment can add up on one RCD; spreading circuits sensibly avoids unwanted trips.


RCD work is often combined with distribution board upgrades or new industrial lighting, so the whole installation is brought up to date with less downtime.


Testing, certification and maintenance


New circuits and major alterations should come with an Electrical Installation Certificate (EIC) to BS 7671. RCD test buttons should be pressed regularly; Electrical Safety First recommends every six months, and harsh environments may justify more often. Fixed installations need periodic inspection and testing, with the interval set by the inspector according to the type of site, its use and its condition; regular industrial electrical inspections help you meet your EAWR maintenance duty. If you are reviewing energy costs as well, the industrial solar comparison tool lets you compare renewable specialists. Submit your project details, compare quotes from local electricians, or call Kilowatts UK free on 0800 009 6058.

A simpler way to get started

Move forward with confidence

Describe the work

Share what you need, whether you have a detailed plan or are still exploring the options.

Compare your options

Review quotes in your account and compare the details that matter to your project.

Choose your next step

Make an informed decision about the work, timing and provider that suit you.

Industrial

Let's get your Industrial RCD Services project started.

Tell us a little about this industrial site Industrial RCD Services work and we'll help you take the next step.

Your request is kept together in your account, so it is easy to come back to.

Industrial project

Request Industrial RCD Services quotes

If Industrial RCD Services isn't what you're looking for, explore more General Electrical Work services.

Please enter your email

Please enter your requirements description

Please enter your location postcode

Please enter your budget max

Please enter your name

Please enter your phone

FAQ

Need Help? RoboMo's Got Answers

Where are RCDs needed on an industrial site?
BS 7671 requires 30 mA RCD protection for new socket circuits up to 32 A, unless a documented risk assessment justifies omitting it, and for mobile equipment used outdoors. Wet, dusty and outdoor areas and places where portable tools are used are the priority.
Can RCDs protect three-phase equipment?
Yes. Three-phase RCDs and RCBOs are available. The electrician will choose the rating and type to suit the load, including Type F or Type B devices where drives or inverters are involved.
How do I stop RCDs tripping the whole site?
Good design uses time-delayed RCDs upstream and 30 mA devices on final circuits, so only the nearest device trips. Spreading equipment across circuits also stops leakage from adding up on one RCD.
How often should industrial RCDs be tested?
Press the test button regularly; Electrical Safety First recommends every six months, and harsh environments may justify more often. Full testing is part of periodic inspection, at an interval set by the inspector.