Sigenergy Sigen Gateway HomePro TP
Sold by
Sigen Gateway HomePro TP: three-phase energy gateway rated at 30.00 kW, with 45.6 A nominal AC current. Check compatible inverters, backup circuits and installation requirements.
RRP inc VAT
£1,030.00
Price on application
SKU: SIGEN-GW-HOMEPRO-TP Pre-order - expected in stock by 23 Nov 2026
Choose options
Pick an option to see price and stock.
RRP inc VAT: £1,030.00 · Pre-order - expected in stock by 23 Nov 2026
That combination is not available.
Delivery: £49.99 UK mainland; £99.99 Scottish Highlands; Scottish islands, Isles of Scilly, Isle of Wight, Northern Ireland, Isle of Man and Channel Islands: quote on request.
Get an installation quote
Have this specified, supplied and installed by an installer.
Sigen Gateway HomePro TP
The Sigenergy Sigen Gateway HomePro TP is an energy gateway for coordinating the inverter, battery, grid connection and backed-up circuits. It is listed for three-phase systems with nominal AC power of 30.00 kW. A gateway is a system component, so compatibility and installation design are as important as the headline rating.
Specification at a glance
| Brand / model | Sigenergy Sigen Gateway HomePro TP |
|---|---|
| Phase | three |
| Nominal AC power | 30.00 kW |
| Nominal AC current | 45.6 A |
| Nominal voltage | 380 / 400 V |
| Backup switch figure | Not stated |
| IP rating | Not stated in the catalogue |
| Dimensions | 450 x 695 x 163 mm |
| Weight | Not stated |
| Compatible equipment | 1 SigenStor |
What the gateway does
The gateway manages the boundary between normal grid operation and the energy system's backup or smart-load operation. Depending on the complete system, it can help the inverter identify grid status, control selected circuits and coordinate storage during an outage. The published backup-switch figure is a component specification, not a promise that every appliance will remain powered; the installer must define the backed-up loads, protection, earthing and changeover arrangement.
Compatibility and installation
Confirm the exact inverter and battery family, firmware, phase arrangement and communications requirements before ordering. The electrical contractor should check service capacity, cable sizes, protection, enclosure location, clearances, Wi-Fi or wired communications and any DNO conditions. Do not assume a single-phase gateway can serve a three-phase installation, or that every household circuit can be placed behind backup. The datasheet and current installation manual take precedence over a summary listing.
Buying checklist
- Exact gateway model and phase match the system design.
- Nominal power and current are sufficient for the intended backed-up loads.
- Compatibility with the selected inverter, battery and monitoring platform is confirmed.
- Backup circuits, changeover and isolation are documented in the quotation.
- Commissioning, firmware, user access and aftercare are included.
Next step
Request a system design around the exact gateway above. Kilowatts can verify the phase, load profile, backup priorities and installation requirements before confirming the complete equipment list.
Open the manufacturer datasheet for the latest installation limits.
Specifications
| Brand | Sigenergy |
|---|---|
| Model | Sigen Gateway HomePro TP |
| Phase | three |
| Nominal AC power | 30.00 kW |
| Nominal current | 45.6 A |
| Nominal voltage | 380 / 400 V |
| Backup switch | 0 ms |
| Dimensions | 450 x 695 x 163 mm |
| Works with | 1 SigenStor |